FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.16  |  FHIR Version n/a  User: [n/a]

Resource StructureDefinition/FHIR Server from package de.medizininformatikinitiative.use-case.omi#0.3.13 (94 ms)

Package de.medizininformatikinitiative.use-case.omi
Type StructureDefinition
Id Id
FHIR Version R4
Source https://simplifier.net/resolve?scope=de.medizininformatikinitiative.use-case.omi@0.3.13&canonical=http://omi.de/fhir/registry/StructureDefinition/BodServiceInputParameters
Url http://omi.de/fhir/registry/StructureDefinition/BodServiceInputParameters
Version 0.3.13
Status active
Date 2024-12-11
Name BodServiceInputParameters
Title BodServiceInputParameters
Experimental False
Realm de
Description BodServiceInputParameters
Type Parameters
Kind resource

Resources that use this resource

No resources found


Resources that this resource uses

StructureDefinition
http://omi.de/fhir/registry/StructureDefinition/omi-service-input-parameter Omi Input Parameter


Source

{
  "resourceType" : "StructureDefinition",
  "id" : "BodServiceInputParameters",
  "url" : "http://omi.de/fhir/registry/StructureDefinition/BodServiceInputParameters",
  "version" : "0.3.13",
  "name" : "BodServiceInputParameters",
  "title" : "BodServiceInputParameters",
  "status" : "active",
  "date" : "2024-12-11",
  "publisher" : "MOLIT gGmbH",
  "description" : "BodServiceInputParameters",
  "fhirVersion" : "4.0.1",
  "kind" : "resource",
  "abstract" : false,
  "type" : "Parameters",
  "baseDefinition" : "http://omi.de/fhir/registry/StructureDefinition/omi-service-input-parameter",
  "derivation" : "constraint",
  "differential" : {
    "element" : [
      {
        "id" : "Parameters.parameter",
        "path" : "Parameters.parameter",
        "min" : 1
      },
      {
        "id" : "Parameters.parameter:imagingStudy",
        "path" : "Parameters.parameter",
        "sliceName" : "imagingStudy",
        "max" : "1"
      },
      {
        "id" : "Parameters.parameter:imagingStudy.resource",
        "path" : "Parameters.parameter.resource",
        "constraint" : [
          {
            "key" : "mii-imageType-localizer",
            "severity" : "error",
            "human" : "ImageType extension string must contain 'LOCALIZER', returns true if it does",
            "expression" : "ImagingStudy.series.instance.extension('https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-instanz-details').extension('imageType').valueCodeableConcept.coding.where(system = 'https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/CodeSystem/mii-cs-bildgebung-instance-image-type' and code = 'LOCALIZER').exists()",
            "source" : "http://omi.de/fhir/registry/StructureDefinition/BodServiceInputParameters"
          },
          {
            "key" : "mii-instance-imageType-checker",
            "severity" : "error",
            "human" : "Returns true if there is at most one instance with an imageType that contains `LOCALIZER`",
            "expression" : "ImagingStudy.series.instance.extension('https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-instanz-details').extension('imageType').valueCodeableConcept.coding.where(system = 'https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/CodeSystem/mii-cs-bildgebung-instance-image-type' and code = 'LOCALIZER').count() <= 1",
            "source" : "http://omi.de/fhir/registry/StructureDefinition/BodServiceInputParameters"
          }
        ]
      },
      {
        "id" : "Parameters.parameter:image-binary",
        "path" : "Parameters.parameter",
        "sliceName" : "image-binary",
        "min" : 1,
        "max" : "1"
      }
    ]
  },
  "text" : {
  }
}